Descripción general:
The ECELL EP12-150C is a heavy-duty, high-capacity Valve Regulated Lead-Acid (VRLA) battery engineered with advanced AGM technology for mission-critical power backup. With a substantial 150Ah capacity, this EP series model is optimized for long-duration discharge and high-reliability standby use. It is specifically designed to provide seamless energy continuity for large-scale UPS systems, renewable energy storage, and industrial-grade emergency equipment where power failure is not an option.
Batería SAI AGM de 12 V
ECELL EP12-150C | Batería SAI VRLA AGM de alto rendimiento de 12 V y 150 Ah
Descripción detallada
| Artículo | Especificación |
| Número de modelo | EP12-150C |
| Voltaje nominal | 12 V |
| Capacidad nominal | 150Ah (20HR) / 135Ah (10HR) |
| Diseño de vida | 10 – 12 Years (Standby) |
| Energía total | 1800Wh |
| Corriente máxima de descarga | 1200A (5 Seconds) |
| Operating Temp Range | Discharge: -20°C to 55°C |
| Resistencia interna | ≤ 3.5mΩ (Full Charged) |
| Tipo de terminal | T11 (perno M8) |
| Dimensiones (largo x ancho x alto) | 340 x 173 x 281 mm |
| Peso aproximado | 45.50 kg |
Características principales:
・Premium Long-Life Design: Engineered with thickened high-purity lead plates to achieve an extended design life of up to 10-12 years in standby applications.
・Exceptional Cyclic Endurance: The EP-C (Deep Cycle) construction offers superior recovery and stability during repeated deep discharge cycles.
・Baja resistencia interna: Optimized for high-current delivery, making it perfect for driving large inverters and industrial UPS loads.
・Maintenance-Free & Non-Spillable: Utilizing oxygen recombination technology, this battery requires zero watering and can be installed in various orientations without leakage risk.
・Ultra-Low Self-Discharge: High-quality separators and lead-calcium alloys allow for extended storage periods with minimal energy loss.
・Reinforced Thermal Stability: Housed in a flame-retardant, high-strength ABS case (UL94-HB/V0 optional) to withstand fluctuating industrial temperatures.
Especificación:
| Serie | BATERÍAS ECELL Modelo | Voltaje V | Capacidad (10 horas) Ah | Dimensión (mm)±1,5 | Peso (kg)±3% | Tipo | |||
| L | W | H | EL | ||||||
| EP | EP12-30 | 12 | 30 | 195 | 130 | 152 | 166 | 9.6 | Asamblea general anual de VRLA |
| EP12-33 | 12 | 33 | 195 | 130 | 152 | 166 | 10.2 | Asamblea general anual de VRLA | |
| EP12-35 | 12 | 35 | 197 | 165 | 175 | 175 | 11.5 | Asamblea general anual de VRLA | |
| EP12-38 | 12 | 38 | 197 | 165 | 175 | 175 | 12.5 | Asamblea general anual de VRLA | |
| EP12-40 | 12 | 40 | 197 | 165 | 175 | 175 | 12.75 | Asamblea general anual de VRLA | |
| EP12-42 | 12 | 42 | 197 | 165 | 175 | 175 | 13.5 | Asamblea general anual de VRLA | |
| EP12-45 | 12 | 45 | 197 | 165 | 175 | 175 | 14.7 | Asamblea general anual de VRLA | |
| EP12-50 | 12 | 50 | 229 | 138 | 205 | 210 | 15.5 | Asamblea general anual de VRLA | |
| EP12-55A | 12 | 55 | 229 | 138 | 211 | 214 | 16 | Asamblea general anual de VRLA | |
| EP12-55 | 12 | 55 | 229 | 138 | 211 | 214 | 16.5 | Asamblea general anual de VRLA | |
| EP12-55HR | 12 | 55 | 229 | 138 | 211 | 214 | 17.5 | Asamblea general anual de VRLA | |
| EP12-60 | 12 | 60 | 229 | 138 | 205 | 210 | 16.7 | Asamblea general anual de VRLA | |
| EP12-65 | 12 | 65 | 350 | 167 | 174 | 174 | 20 | Asamblea general anual de VRLA | |
| EP12-75 | 12 | 75 | 260 | 168 | 211 | 214 | 21.5 | Asamblea general anual de VRLA | |
| EP12-80 | 12 | 80 | 260 | 168 | 211 | 214 | 22.5 | Asamblea general anual de VRLA | |
| EP12-90 | 12 | 90 | 306 | 169 | 211 | 214 | 27 | Asamblea general anual de VRLA | |
| EP12-100S | 12 | 100 | 305 | 167 | 210 | 213 | 28.5 | Asamblea general anual de VRLA | |
| EP12-100B | 12 | 100 | 330 | 171 | 214 | 217 | 27.3 | Asamblea general anual de VRLA | |
| EP12-100 | 12 | 100 | 330 | 171 | 214 | 220 | 29.5 | Asamblea general anual de VRLA | |
| EP12-100A | 12 | 100 | 330 | 171 | 214 | 220 | 30.3 | Asamblea general anual de VRLA | |
| EP12-105 | 12 | 105 | 330 | 171 | 214 | 220 | 31 | Asamblea general anual de VRLA | |
| EP12-110 | 12 | 110 | 330 | 171 | 214 | 220 | 33.7 | Asamblea general anual de VRLA | |
| EP12-120 | 12 | 120 | 406 | 173 | 208 | 238 | 34 | Asamblea general anual de VRLA | |
| EP12-120L | 12 | 120 | 409 | 176 | 225 | 225 | 34 | Asamblea general anual de VRLA | |
| EP12-150 | 12 | 150 | 485 | 172 | 240 | 240 | 43 | Asamblea general anual de VRLA | |
| EP12-150A | 12 | 150 | 485 | 172 | 240 | 240 | 45 | Asamblea general anual de VRLA | |
| EP12-150C | 12 | 150 | 340 | 173 | 281 | 284 | 45.5 | Asamblea general anual de VRLA | |
| EP12-150B | 12 | 150 | 522 | 238 | 218 | 221 | 51.5 | Asamblea general anual de VRLA | |
| EP12-160B | 12 | 160 | 522 | 238 | 218 | 221 | 52 | Asamblea general anual de VRLA | |
| EP12-200L | 12 | 200 | 522 | 238 | 218 | 221 | 57 | Asamblea general anual de VRLA | |
| EP12-180 | 12 | 180 | 530 | 207 | 210 | 213 | 52.5 | Asamblea general anual de VRLA | |
| EP12-190 | 12 | 190 | 530 | 207 | 210 | 213 | 55 | Asamblea general anual de VRLA | |
| EP12-200 | 12 | 200 | 522 | 238 | 218 | 221 | 59 | Asamblea general anual de VRLA | |
| EP12-200B | 12 | 200 | 522 | 238 | 218 | 221 | 59.5 | Asamblea general anual de VRLA | |
| EP12-200A | 12 | 200 | 522 | 238 | 218 | 221 | 61 | Asamblea general anual de VRLA | |
| EP12-220 | 12 | 220 | 522 | 238 | 218 | 221 | 61.5 | Asamblea general anual de VRLA | |
| EP12-250 | 12 | 250 | 521 | 269 | 220 | 223 | 71 | Asamblea general anual de VRLA | |
¿POR QUÉ BATERÍAS ECELL?
When your operations depend on 100% uptime, the ECELL EP Series is your most trusted energy partner.
-
Industrial-Grade Consistency: Each EP12-150C unit is subjected to rigorous computerized discharge testing to ensure matched capacity and voltage across every batch.
-
Pure Virgin Lead: We use 99.99% pure virgin lead to maximize plate life and minimize the degradation common in recycled-material alternatives.
-
Engineered for Reliability: From the thickness of the grids to the quality of the AGM separators, every component is selected to withstand the stresses of deep discharge and float charging.
-
Global Compliance & Safety: Manufactured under strict ISO 9001/14001 standards and certified by CE/UL, ensuring our batteries meet the highest global safety benchmarks.
¿Listo para impulsar su próximo proyecto?
Nuestros ingenieros técnicos están disponibles para brindarle hojas de datos detalladas, precios por volumen y soluciones energéticas personalizadas.
ECELL BATTERIES ¡Les desea a usted y a su familia una Feliz Navidad y un Feliz Año Nuevo 2026!
Agradecemos su consulta
Hemos construido un sistema de calificación autorizado que abarca toda la cadena de I+D, producción, ventas y servicio.
-
Servicio 24/7 -
Habitación 302, Bloque C, Parque de Software, Avenida Software No. 89, Distrito Gulou, Ciudad de Fuzhou, Provincia de Fujian, China.
Escenarios de aplicación:
-
Vehículos eléctricos
-
Instalaciones de telecomunicaciones
-
Sistemas de control de acceso y seguridad
-
Equipo médico
-
Bicicletas y patinetes eléctricos
-
Cortacésped
-
Sistemas de alimentación ininterrumpida
-
Batería de carros de golf y tracción
-
Almacenamiento de energía solar y energía eólica
-
Sistemas de seguridad con iluminación de emergencia y CCTV
-
Alumbrado público y semáforos
-
Red de suministro eléctrico e industria energética
-
Centros de procesamiento de datos
-
Equipos de limpieza de pisos
-
Sillas de ruedas
-
Sistemas de seguridad y protección