Overview:
EC Series - AGM UPS Battery 12V 1.2Ah to 30Ah
ECELL EC6-4.5 | 6V 4.5Ah AGM UPS BATTERY
Detailed Description
Key Features:
・ 99.996% High-Purity Lead: Features premium 99.996% pure lead plates to minimize internal impurities, significantly reducing self-discharge and extending service life.
・ Maintenance-Free Operation: Sealed VRLA construction allows for safe operation in any position without the need to add water or electrolyte.
・ High-Rate Discharge Performance: Optimized plate design and low internal resistance deliver high power output, perfect for critical UPS demands.
・ Long Service Life: Heavy-duty lead-calcium grids resist corrosion, providing a design life of 5-10 years in float service applications.
・ Low Self-Discharge: High-purity raw materials ensure a self-discharge rate of less than 3% per month (at 25°C), allowing for long shelf storage.
・ High-Power & Durable:Designed with military-gradehigh-performance AGM separators, optimized for high-current discharge. Capable ofhandling large instantaneous loads to meet short-term high-power demands.
・ Stable & Reliable Energy:Combining high energy densitywith excellent discharge efficiency, delivering stablepower-ideal for precision equipment and ensuring the reliable operation of criticalsystems.
・ 15-Minute Colden Backup:High-tin, low-calcium alloy gridspaired with a high-power leadpaste formula enable instanthigh-current output, providing dependable emergency backup for short-duration power needs.
・ Safety & Reliability: Equipped with explosion-proof safety valves and rugged ABS containers (UL94-V0 optional) to ensure operational safety.
Specification:
| Series | ECELL BATTERIES Model | Voltage V | Capacity (20HR) Ah | Dimension (mm)±1.5 | Weight (kg)±3% | Type | |||
| L | W | H | TH | ||||||
| EC | EC4-4.5 | 4 | 4.5 | 47 | 47 | 100 | 104 | 0.47 | VRLA AGM |
| EC4-7.5 | 4 | 7.5 | 47 | 47 | 100 | 104 | 0.82 | VRLA AGM | |
| EC6-1.3 | 6 | 1.3 | 97 | 24 | 52 | 58 | 0.29 | VRLA AGM | |
| EC6-3.2 | 6 | 3.2 | 134 | 35 | 61 | 67 | 0.65 | VRLA AGM | |
| EC6-4 | 6 | 4 | 70 | 47 | 101 | 107 | 0.68 | VRLA AGM | |
| EC6-4.5 | 6 | 4.5 | 70 | 47 | 101 | 107 | 0.72 | VRLA AGM | |
| EC6-5 | 6 | 5 | 70 | 47 | 101 | 107 | 0.8 | VRLA AGM | |
| EC6-7 | 6 | 7 | 151 | 35 | 94 | 100 | 1.09 | VRLA AGM | |
| EC6-7.5 | 6 | 7.5 | 151 | 35 | 94 | 100 | 1.18 | VRLA AGM | |
| EC6-9 | 6 | 9 | 151 | 35 | 94 | 100 | 1.31 | VRLA AGM | |
| EC6-10 | 6 | 10 | 151 | 50 | 94 | 100 | 1.55 | VRLA AGM | |
| EC6-12 | 6 | 12 | 151 | 50 | 94 | 100 | 1.75 | VRLA AGM | |
| EC12-1.3 | 12 | 1.3 | 97 | 43 | 52 | 58 | 0.55 | VRLA AGM | |
| EC12-2.3 | 12 | 2.3 | 178 | 35 | 61 | 67 | 0.9 | VRLA AGM | |
| EC12-2.6 | 12 | 2.6 | 70 | 48 | 98 | 104 | 0.78 | VRLA AGM | |
| EC12-2.9 | 12 | 2.9 | 79 | 56 | 99 | 105 | 1.05 | VRLA AGM | |
| EC12-3.2 | 12 | 3.2 | 134 | 67 | 61 | 67 | 1.25 | VRLA AGM | |
| EC12-4 | 12 | 4 | 90 | 70 | 101 | 107 | 1.36 | VRLA AGM | |
| EC12-4L | 12 | 4 | 195 | 47 | 70 | 76 | 1.42 | VRLA AGM | |
| EC12-4.5 | 12 | 4.5 | 90 | 70 | 101 | 107 | 1.43 | VRLA AGM | |
| EC12-5 | 12 | 5 | 90 | 70 | 101 | 107 | 1.5 | VRLA AGM | |
| EC12-5A | 12 | 5 | 90 | 70 | 101 | 107 | 1.6 | VRLA AGM | |
| EC12-5HR | 12 | 5 | 90 | 70 | 101 | 107 | 1.83 | VRLA AGM | |
| EC12-6 | 12 | 6 | 151 | 65 | 94 | 100 | 1.88 | VRLA AGM | |
| EC12-6.5 | 12 | 6.5 | 151 | 65 | 94 | 100 | 1.99 | VRLA AGM | |
| EC12-7 | 12 | 7 | 151 | 65 | 94 | 100 | 2.05 | VRLA AGM | |
| EC12-7.2 | 12 | 7.2 | 151 | 65 | 94 | 101 | 2.1 | VRLA AGM | |
| EC12-7.5 | 12 | 7.5 | 151 | 65 | 94 | 100 | 2.2 | VRLA AGM | |
| EC12-8 | 12 | 8 | 151 | 65 | 94 | 100 | 2.3 | VRLA AGM | |
| EC12-8.5 | 12 | 8.5 | 151 | 65 | 94 | 100 | 2.45 | VRLA AGM | |
| EC12-9 | 12 | 9 | 151 | 65 | 94 | 100 | 2.52 | VRLA AGM | |
| EC12-9HR | 12 | 9 | 151 | 65 | 94 | 100 | 2.7 | VRLA AGM | |
| EC12-10 | 12 | 10 | 151 | 98 | 95 | 101 | 3.15 | VRLA AGM | |
| EC12-10L | 12 | 10 | 151 | 65 | 111 | 117 | 2.75 | VRLA AGM | |
| EC12-12 | 12 | 12 | 151 | 98 | 95 | 101 | 3.45 | VRLA AGM | |
| EC12-12A | 12 | 12 | 151 | 98 | 95 | 101 | 3.6 | VRLA AGM | |
| EC12-12B | 12 | 12 | 151 | 98 | 95 | 101 | 3.9 | VRLA AGM | |
| EC12-17 | 12 | 17 | 181 | 77 | 167 | 167 | 5 | VRLA AGM | |
| EC12-18 | 12 | 18 | 181 | 77 | 167 | 167 | 5.3 | VRLA AGM | |
| EC12-20 | 12 | 20 | 181 | 77 | 167 | 167 | 5.7 | VRLA AGM | |
| EC12-24H | 12 | 24 | 165 | 125 | 175 | 175 | 7.5 | VRLA AGM | |
| EC12-24 | 12 | 24 | 166 | 175 | 125 | 125 | 7.6 | VRLA AGM | |
| EC12-26 | 12 | 26 | 166 | 175 | 125 | 125 | 7.9 | VRLA AGM | |
| EC12-28H | 12 | 28 | 165 | 125 | 175 | 175 | 8.1 | VRLA AGM | |
| EC12-28 | 12 | 28 | 166 | 175 | 125 | 125 | 8.2 | VRLA AGM | |
| EC24-3.5 | 24 | 3.5 | 179 | 70 | 101 | 106 | 2.61 | VRLA AGM | |
| EC24-4 | 24 | 4 | 179 | 70 | 101 | 106 | 2.75 | VRLA AGM | |
| EC24-5 | 24 | 5 | 179 | 70 | 101 | 106 | 2.91 | VRLA AGM | |
FAQ 1: Why are ECELL BATTERIES Lead-Acid batteries still a reliable choice for various industries?
Despite the rise of lithium, the Lead-Acid solutions from ECELL BATTERIES remain a global standard due to:
- Proven Reliability: With decades of technological maturity, ECELL BATTERIES Lead-Acid products offer stable performance in even the most demanding environments.
- Unbeatable Cost-Efficiency: They provide the lowest initial investment cost, making them the most economical choice for large-scale backup power and starting applications.
- High Recyclability: Over 98% of the materials in an ECELL BATTERIES lead-acid battery are recyclable, supporting a highly effective circular economy.
- Excellent Cold-Cranking Performance: Our batteries excel in cold climates, providing the high burst of current (CCA) needed to start heavy-duty engines in freezing temperatures.
- Wide Operating Temperature Range: They are remarkably resilient to a broad range of temperatures without requiring complex thermal management systems.
- Superior Safety Profile: Lead-acid chemistry is inherently non-flammable and stable, making ECELL BATTERIES a trusted choice for critical infrastructure safety.
FAQ 2: How do ECELL BATTERIES VRLA (AGM/Gel) batteries differ from conventional flooded batteries?
ECELL BATTERIES specializes in Maintenance-Free Valve Regulated Lead-Acid (VRLA) technology, which offers:
- Maintenance-Free Operation: Our AGM and Gel batteries are sealed, eliminating the need to check electrolyte levels or add distilled water.
- Leak-Proof Design: The “starved electrolyte” in AGM or the silica-based Gel ensures the battery is spill-proof, allowing for flexible installation in various orientations.
- Low Self-Discharge: ECELL BATTERIES VRLA models use high-purity lead-calcium alloys, allowing for longer shelf life and reduced power loss during storage.
- Enhanced Vibration Resistance: The internal compression of our AGM plates provides superior resistance to mechanical shock, ideal for rugged transport and marine use.
- Gas Recombination Technology: Our internal valve system recombines generated gases back into water, ensuring no corrosive fumes are released under normal operating conditions.
- Optimized for Deep Cycling: Specifically designed for solar and UPS backup, ECELL BATTERIES Gel series offer better recovery from deep discharge compared to standard starter batteries.
FAQ 3: What are the best practices for maintaining ECELL BATTERIES Lead-Acid products?
To maximize the service life of your ECELL BATTERIES lead-acid investment, please follow these maintenance protocols:
- Avoid Deep Discharge: Lead-acid batteries prefer to stay near 100% charge; try not to discharge your ECELL BATTERIES below 50% capacity to prevent sulfation.
- Prompt Recharging: Always recharge the battery immediately after use. Leaving a lead-acid battery in a discharged state for long periods will lead to permanent capacity loss.
- Temperature Control: High heat is the enemy of lead-acid; storing your ECELL BATTERIES in a cool, dry place (approx. 25°C) can significantly extend their chemical life.
- Correct Charging Voltage: Use a high-quality multi-stage charger with the correct “Bulk” and “Float” voltage settings to prevent overcharging or gassing.
- Terminal Cleanliness: Keep the terminals of your ECELL BATTERIES clean and apply a thin layer of petroleum jelly or terminal spray to prevent oxidation and corrosion.
- Regular Float Charging: For backup applications (like UPS), ensure the battery is kept on a continuous float charge to keep it healthy and ready for a power outage.
Welcomes Your Consultation
We have built an authoritative qualification system that spans the entire chain of R&D, production, sales and service.
-
24/7 service -
Room 302, Block C, Software Park, No. 89 Software Avenue, Gulou District, Fuzhou City, Fujian Province, China.
Application Scenarios:
-
Electric Vehicles
-
Telecommunication Facilities
-
Access Control and Security Systems
-
Medical Equipment
-
Electric Bikes and Scooters
-
Lawn Mower
-
Uninterruptible Power Supplies
-
Golf Cars & Motive Power Battery
-
Solar Power Storage Energy And Wind Power
-
Emergency Lighting And CCTV Security Systems
-
Street lighting and traffic lights
-
Electrical Supply Network and Power Industry
-
Data Processing Centers
-
Floor Cleaning Equipment
-
Wheelchairs
-
Security and safety systems
Similar Products
Other products you might like
-

ECELL EC12-7 | 12V 7Ah SLA AGM Battery for UPS
Inquire Now -

ECELL EC12-5 | 12V 5Ah AGM UPS BATTERY
Inquire Now