Overview:

The ECELL BATTERIES EC12-18 is a premium 12V 18Ah valve-regulated lead-acid battery designed for applications that demand high reliability in a compact form factor. Engineered with elite-grade AGM separators, this model serves as a "high-endurance" energy reservoir, bridging the gap between small backup cells and large industrial blocks. It is specifically crafted to provide sustained, stable current for critical systems that require a higher capacity buffer to handle extended operational cycles without performance degradation.

Application Scenarios:
・Critical Fire & Safety Systems: Reliable backup for large-scale fire panels, sprinkler control systems, and voice evacuation alarms.
・Enterprise UPS Backup: Supporting mid-range servers and network storage arrays (NAS) during unexpected power transitions.
 

Share:

  • Detailed Description

Key Features:

Technical Quick-Look:
Nominal Voltage: 12V
Capacity (20HR): 18Ah
Technology: VRLA AGM
Terminal Type: L1/M5 (Copper Terminalsb)
Self-Discharge: <3% per month


Heavy-Duty Grid Architecture: Utilizes a thicker lead-calcium-tin alloy grid to significantly enhance resistance against plate corrosion, ensuring a longer service life.

Superior Vibration Dampening: The internal assembly is tightly packed to withstand high-frequency mechanical vibrations, making it suitable for mobile and industrial environments.

Low Self-Discharge Chemistry: Features high-purity raw materials that maintain charge integrity, allowing for up to 6 months of storage without requiring a boost charge.

Multifaceted Installation: The spill-proof and leak-proof construction allows the battery to be safely mounted in various positions to suit narrow equipment cabinets.

High Recombination Efficiency: Achieves over 99% gas recombination, effectively eliminating the need for electrolyte maintenance and preventing acid misting.

Thermal Runaway Protection: Designed with advanced safety valves that regulate internal pressure, protecting the battery during high-ambient temperature operation.

Specification:

SeriesECELL BATTERIES
Model
Voltage
V
Capacity (20HR)
Ah
Dimension (mm)±1.5Weight
 (kg)±3%
Type
LWHTH
ECEC4-4.544.547471001040.47VRLA AGM
EC4-7.547.547471001040.82VRLA AGM
EC6-1.361.3972452580.29VRLA AGM
EC6-3.263.21343561670.65VRLA AGM
EC6-46470471011070.68VRLA AGM
EC6-4.564.570471011070.72VRLA AGM
EC6-56570471011070.8VRLA AGM
EC6-76715135941001.09VRLA AGM
EC6-7.567.515135941001.18VRLA AGM
EC6-96915135941001.31VRLA AGM
EC6-1061015150941001.55VRLA AGM
EC6-1261215150941001.75VRLA AGM
EC12-1.3121.3974352580.55VRLA AGM
EC12-2.3122.31783561670.9VRLA AGM
EC12-2.6122.67048981040.78VRLA AGM
EC12-2.9122.97956991051.05VRLA AGM
EC12-3.2123.21346761671.25VRLA AGM
EC12-412490701011071.36VRLA AGM
EC12-4L1241954770761.42VRLA AGM
EC12-4.5124.590701011071.43VRLA AGM
EC12-512590701011071.5VRLA AGM
EC12-5A12590701011071.6VRLA AGM
EC12-5HR12590701011071.83VRLA AGM
EC12-612615165941001.88VRLA AGM
EC12-6.5126.515165941001.99VRLA AGM
EC12-712715165941002.05VRLA AGM
EC12-7.2127.215165941012.1VRLA AGM
EC12-7.5127.515165941002.2VRLA AGM
EC12-812815165941002.3VRLA AGM
EC12-8.5128.515165941002.45VRLA AGM
EC12-912915165941002.52VRLA AGM
EC12-9HR12915165941002.7VRLA AGM
EC12-10121015198951013.15VRLA AGM
EC12-10L1210151651111172.75VRLA AGM
EC12-12121215198951013.45VRLA AGM
EC12-12A121215198951013.6VRLA AGM
EC12-12B121215198951013.9VRLA AGM
EC12-171217181771671675VRLA AGM
EC12-181218181771671675.3VRLA AGM
EC12-201220181771671675.7VRLA AGM
EC12-24H12241651251751757.5VRLA AGM
EC12-2412241661751251257.6VRLA AGM
EC12-2612261661751251257.9VRLA AGM
EC12-28H12281651251751758.1VRLA AGM
EC12-2812281661751251258.2VRLA AGM
EC24-3.5243.5179701011062.61VRLA AGM
EC24-4244179701011062.75VRLA AGM
EC24-5245179701011062.91VRLA AGM

Why Choose ECELL EC Series?

  • 99.996% Ultra-High Purity Lead Plates: We use the industry’s highest standard of lead purity to ensure minimal self-discharge and maximum battery life.

  • Maintenance-Free Convenience: Our sealed VRLA construction eliminates the need for watering or electrolyte checks.

  • Proven Reliability: Designed for a 5-10 year service life in float applications, providing peace of mind for critical backup systems.

  • Certified Safety: Every battery is equipped with explosion-proof safety valves and rugged ABS casing.


Ready to Power Your Next Project?

Our technical engineers are standing by to provide you with detailed datasheets, volume pricing, and custom energy solutions.

 

FAQ 1: Why are ECELL BATTERIES Lead-Acid batteries still a reliable choice for various industries?olutions from ECELL BATTERIES remain a global standard due to:

  1. Proven Reliability: With decades of technological maturity, ECELL BATTERIES Lead-Acid products offer stable performance in even the most demanding environments.
  2. Unbeatable Cost-Efficiency: They provide the lowest initial investment cost, making them the most economical choice for large-scale backup power and starting applications.
  3. High Recyclability: Over 98% of the materials in an ECELL BATTERIES lead-acid battery are recyclable, supporting a highly effective circular economy.
  4. Excellent Cold-Cranking Performance: Our batteries excel in cold climates, providing the high burst of current (CCA) needed to start heavy-duty engines in freezing temperatures.
  5. Wide Operating Temperature Range: They are remarkably resilient to a broad range of temperatures without requiring complex thermal management systems.
  6. Superior Safety Profile: Lead-acid chemistry is inherently non-flammable and stable, making ECELL BATTERIES a trusted choice for critical infrastructure safety.

FAQ 2: How do ECELL BATTERIES VRLA (AGM/Gel) batteries differ from conventional flooded batteries?

ECELL BATTERIES specializes in Maintenance-Free Valve Regulated Lead-Acid (VRLA) technology, which offers:

  1. Maintenance-Free Operation: Our AGM and Gel batteries are sealed, eliminating the need to check electrolyte levels or add distilled water.
  2. Leak-Proof Design: The “starved electrolyte” in AGM or the silica-based Gel ensures the battery is spill-proof, allowing for flexible installation in various orientations.
  3. Low Self-Discharge: ECELL BATTERIES VRLA models use high-purity lead-calcium alloys, allowing for longer shelf life and reduced power loss during storage.
  4. Enhanced Vibration Resistance: The internal compression of our AGM plates provides superior resistance to mechanical shock, ideal for rugged transport and marine use.
  5. Gas Recombination Technology: Our internal valve system recombines generated gases back into water, ensuring no corrosive fumes are released under normal operating conditions.
  6. Optimized for Deep Cycling: Specifically designed for solar and UPS backup, ECELL BATTERIES Gel series offer better recovery from deep discharge compared to standard starter batteries.

FAQ 3: What are the best practices for maintaining ECELL BATTERIES Lead-Acid products?

To maximize the service life of your ECELL BATTERIES lead-acid investment, please follow these maintenance protocols:

  1. Avoid Deep Discharge: Lead-acid batteries prefer to stay near 100% charge; try not to discharge your ECELL BATTERIES below 50% capacity to prevent sulfation.
  2. Prompt Recharging: Always recharge the battery immediately after use. Leaving a lead-acid battery in a discharged state for long periods will lead to permanent capacity loss.
  3. Temperature Control: High heat is the enemy of lead-acid; storing your ECELL BATTERIES in a cool, dry place (approx. 25°C) can significantly extend their chemical life.
  4. Correct Charging Voltage: Use a high-quality multi-stage charger with the correct “Bulk” and “Float” voltage settings to prevent overcharging or gassing.
  5. Terminal Cleanliness: Keep the terminals of your ECELL BATTERIES clean and apply a thin layer of petroleum jelly or terminal spray to prevent oxidation and corrosion.
  6. Regular Float Charging: For backup applications (like UPS), ensure the battery is kept on a continuous float charge to keep it healthy and ready for a power outage.